Invalid DIMM population error on S2600CP server board
As I purchased this board secondhand, I’m not sure if this is an S2600CP2 or S2600CP4. There is a sticker that reads: PBA E99552-507 QSCP22002137
I have dual Xeon E5-2630L v2 CPUs, and I have 4 x 8GB 1333MHz DDR3 registered, ECC DIMMs on order.
While waiting for these DIMMs to arrive, I decided to test the board with some desktop DIMMs just to make sure that the board is in working order. My understanding is that this board will accept regular desktop DIMMs. According to the «Technical Product Specifications», this board is supposed to support UDIMMs. Unless, there’s such a thing as unregistered server DIMMs, I’m assuming «UDIMMs» is the same as typical desktop DIMMs.
First, I tried to a single 4GB 1333Mhz DDR3 desktop DIMM and got the «Invalid DIMM population» on POST. My understanding is that a single DIMM configuration is supported. I tried this single DIMM in all 4 banks, and got this error each time.
Second, I tried various combinations of 4 x 8GB 1600Mhz DDR3 desktop DIMMs. I’ve used these DIMMs singly, in pairs, and all 4 at a time. I’ve tried filling both slots of 2 channels as well as single slots of 4 channels. I’ve tried a single DIMM in all 4 banks, observing the «farthest fill first» rule.
Another thing to note is that although the «Invalid DIMM population» error appears on the display during POST, the LED POST progress code does not indicate this. According to the specifications, this error SHOULD BE indicated by:
Lower Nibble LEDs (lit green): # 0, # 2, # 3
Upper Nibble LEDs (lit amber): # 5, # 6, # 7
However, in MY CASE, the LEDs are lit as follows:
Lower Nibble LEDs (lit green): # 1, # 2, # 3
Upper Nibble LEDs (lit amber): # 5, # 6, # 7
I don’t even see this combination in the technical specifications.
Here is a video showing the POST progress LED sequence:
Invalid dimm population что это
Success! Subscription added.
Success! Subscription removed.
Sorry, you must verify to complete this action. Please click the verification link in your email. You may re-send via your profile.
Invalid DIMM population error on S2600CP server board
As I purchased this board secondhand, I’m not sure if this is an S2600CP2 or S2600CP4. There is a sticker that reads: PBA E99552-507 QSCP22002137
I have dual Xeon E5-2630L v2 CPUs, and I have 4 x 8GB 1333MHz DDR3 registered, ECC DIMMs on order.
While waiting for these DIMMs to arrive, I decided to test the board with some desktop DIMMs just to make sure that the board is in working order. My understanding is that this board will accept regular desktop DIMMs. According to the «Technical Product Specifications», this board is supposed to support UDIMMs. Unless, there’s such a thing as unregistered server DIMMs, I’m assuming «UDIMMs» is the same as typical desktop DIMMs.
First, I tried to a single 4GB 1333Mhz DDR3 desktop DIMM and got the «Invalid DIMM population» on POST. My understanding is that a single DIMM configuration is supported. I tried this single DIMM in all 4 banks, and got this error each time.
Second, I tried various combinations of 4 x 8GB 1600Mhz DDR3 desktop DIMMs. I’ve used these DIMMs singly, in pairs, and all 4 at a time. I’ve tried filling both slots of 2 channels as well as single slots of 4 channels. I’ve tried a single DIMM in all 4 banks, observing the «farthest fill first» rule.
Another thing to note is that although the «Invalid DIMM population» error appears on the display during POST, the LED POST progress code does not indicate this. According to the specifications, this error SHOULD BE indicated by:
Lower Nibble LEDs (lit green): # 0, # 2, # 3
Upper Nibble LEDs (lit amber): # 5, # 6, # 7
However, in MY CASE, the LEDs are lit as follows:
Lower Nibble LEDs (lit green): # 1, # 2, # 3
Upper Nibble LEDs (lit amber): # 5, # 6, # 7
I don’t even see this combination in the technical specifications.
Here is a video showing the POST progress LED sequence:
Invalid dimm population что это
This chapter describes how to detect and correct problems with the server’s Dual Inline Memory Modules (DIMM)s. It includes the following sections:
The DIMM population rules for the server are as follows:
Replace a DIMM when one of the following events takes place:
In addition, a DIMM should be replaced whenever more than 24 Correctable Errors (CEs) originate in 24 hours from a single DIMM and no other DIMM is showing further CEs.
Retain copies of the logs showing the memory errors per the above rules to send to Sun for verification prior to calling Sun.
This section describes system behavior for the two types of DIMM errors: UCEs and CEs, and also describes BIOS DIMM error messages.
Uncorrectable DIMM Errors
For all operating systems (OS’s), the behavior is the same for UCEs:
1. When an UCE occurs, the memory controller causes an immediate reboot of the system.
2. During reboot, the BIOS checks the Machine Check registers and determines that the previous reboot was due to an UCE, then reports this in POST after the memtest stage:
3. BIOS reports this event in the service processor’s system event log (SEL) as shown in the sample IPMItool output below:
The lines in the display start with event numbers (in hex), followed by a description of the event. TABLE 3-1 describes the contents of the display:
Sun Fire X4140, X4240, and X4440 Servers Diagnostics Guide | 820-3067-14 |
Copyright © 2010, Oracle and/or its affiliates. All rights reserved.
Слоты памяти
Имеется сервер с материнской платой http://www.supermicro.ru/products_spec_868.html 2 процессора Xeon E5606
6 планок памяти по 4Gb уже стояли в синих слотах.
Как это понимать? Спасибо.
DIMM Module Population Configuration в мануале читал? Условия соблюдены?
Вдруг ты не правильно посчитал, давай всем миром пересчитывать: сколько ранков на старых и новых планках?
Или названия моделей сюда.
Вообще в пятницу вечером ковырять боевые сервера — дурное занятие 🙂
память в серверы надо по мануалу втыкать, а не абы как 🙂
Плюсую ранки. Наверняка навтыкал двухранковые с одноранковыми или каналов просто не хватило.
Старые M393B5270DH0-CH9 Rank: 1 Новые M391B5273CH0-CH9 Rank: 2
Одноранковые и двухранковые могут и работать (а могут и не работать)). Главное внимательно смотрите, чтобы суммарного числа ранков хватало, то.е читайте мануал по матплате, и считайте количество ранков (по модулям памяти), по другим форумам погуглите, иногда пишут об этом.
DIMM Slots per Channel: 2 DIMMs Populated per Channel: 1 DIMM Type (Reg.= Registered): Reg. DDR3 ECC 800,1066,1333 Speeds (in MHz): 2 Ranks per DIMM: SR or DR
Судя по всему, вместе они не работают
Я не могу на это ответить, сервера под рукой у меня нет. Я предполагаю, что могут не работать, читайте маны, пробуйте =/
2 2 Reg. DDR3 ECC 800,1066 Mixing SR, DR
Третья строчка в таблице как бы намекает на то, что неплохо было бы частоту опустить до 1066.
Попробуй бутнутся удачно (с одной планкой например) и принудительно ограничить частоту.
BIOS => Chipset control => RAM frequency ()
было Auto, поставил Force 1066.
Supermicro X11SCL-F при запуске зависает на проверке памяти
Сервер supermicro непрерывно пищит при запуске
Здравствуйте! Сервер supermicro непрерывно пищит при запуске и ни чего не выводит на экран. Мать не.
При проверке ЖД Vicorya, программа зависает
Добрый день При проверке ЖД программой виктория, программа зависает при проверке 21639 Мб, также.
при проверке каспером зависает комп!
при проверке каспер доходит до 17% и зависает комп!спасти ситуацию поможет только ресет.я вижу что.
Зависает при проверке жесткого диска
Начал проверять на ошибки винт после перезагрузки запускается прога проверки доходит до 10 процев и.
Зависает ПК, ошибки при проверке sfc /scannow
Часто зависает ПК, 1с (сегодня попробую переустановить платформу). проверка sfc /scannow выявила.
Компьютер зависает при проверке на ошибки после загрузки
После перезагрузки компьютера она начинает проверять диски на ошибки, зависает на 2 стадии на 0%.
Сайт CodeWars при проверке решения выдаёт ошибку, при проверке в VisualStudio ошибки нет
Задача написать метод,который будет проверять порядок круглых скобок. Написал код, проверил в.
Зависает при запуске
Добрый день форумчане! Имеется материнская плата Elitegroup H61H2-M12 (V1.0), при запуске.
Зависает при запуске
После запуска при выходе на рабочий стол, начинает виснуть и не запускается. После 4-5 попытки.
- что делать если котенок чешется
- dpd не доставили посылку вовремя что делать